A Graham condenser is a vital piece of laboratory glassware used for distillation and reflux processes. Its coiled inner tube design maximizes surface area for efficient cooling and condensation of vapors. Selecting the appropriate condenser ensures optimal performance and safety in your scientific applications.

No. 1
Deschem Graham Condenser,24/40,Jacket 200mm,Coil Glass Condenser,Laboratory Glassware
  • Be Made From G3.3 Borosilicate Glass
  • Annealing Point ------560℃
  • Linear Coefficient of Expansion------ 32×10-7/℃
  • Softening Point------820℃
  • Joint 24/40
  • Jacket Length 200mm
No. 2
QWORK Jacket 300mm Glass Graham Condenser with 24/40 Joint for Laboratory
  • High Quality - Glass Condenser is made of high quality glass, which is clear and easy to wash.
  • Specification - Annealing point is 575℃, softening temperature is 820℃, jacket length is 300mm
  • Joint – It has the standard 24/40 joint.
  • Package – Our package incl. one piece of Condenser
No. 3
stonylab Graham Condenser, Borosilicate Glass Graham Condenser with 14/20 Joint 200 mm Jacket Length Lab Glass...
  • StonyLab Graham Condensers are essential components in distillation and reflux units, efficiently condensing vapors when paired with distillation bottles
  • 14/20 joint on the top and bottom; these condensers feature condensate inlet and outlet suitable for 8 mm inner diameter hose, ensuring effective condensation
  • Crafted from premium G3.3 borosilicate glass, these condensers are built to withstand rigorous laboratory use
  • Could be widely used in general laboratory applications
  • Warranty: StonyLab 1-year limited warranty; if received damaged, please contact us immediately; we will solve it until satisfied
No. 4
StonyLab Borosilicate Glass Graham Condenser with 24/40 Joint 300mm Jacket Length Lab Condenser
  • Graham condenser is used for distillation and reflux apparatus, working with distillation flasks and bent adapters to condense vapors and liquid droplets
  • Glass Graham condenser; 24/40 joint on the top and bottom
  • Made of premium glass; maximum withstand temperature 200°C
  • 300mm in jacket length; hose fittings for 3.15in I.D. hoses
  • StonyLab ensures premium products and premium customer service; if received damaged, please contact us immediately; we will solve it until satisfied
No. 5
Labasics Borosilicate Glass Graham Condenser with 24/40 Joint 200mm Jacket Length Lab Glass Condenser
  • Glass Graham condenser
  • 24/40 Joint on the top and bottom
  • Made of Borosilicate glass; maximum withstand temperature 250°C
  • 200 mm in jacket length
  • Labasics ensures premium customer service; If received damaged, please contact us immediately; We will solve it until satisfied
No. 6
Deschem 200mm,24/40,Glass Spiral Reflux Condenser,New Advance Lab Glassware
  • Made From G3.3 Borosilicate Glass
  • Annealing Point ------560℃
  • Linear Coefficient of Expansion------ 32×10-7/℃
  • Softening Point------820℃
  • Deschem Science Supply
No. 7
Deschem 300mm,24/40,Glass Graham Condenser,Coil Heat Exchanger,Laboratory Glassware
  • Annealing Point ------560℃
  • Linear Coefficient of Expansion------ 32×10-7/℃
  • Softening Point------820℃
  • Joint 24/40
  • Jacket Length 300mm
No. 8
stonylab Glass Graham Condenser with 19/22 Joint 200 mm Jacket Length Lab Borosilicate Glass Condenser
  • stonylab Graham Condensers play a crucial role in distillation and reflux units, efficiently condensing vapors in conjunction with distillation bottles
  • These condensers come equipped with a 19/22 joint on the top and bottom, along with a condensate inlet and outlet suitable for 8 mm inner diameter hose, ensuring effective condensation over a 200 mm length
  • Crafted from premium G3.3 borosilicate glass, these condensers boast exceptional durability, making them ideal for withstanding rigorous laboratory use
  • Could be widely used in general laboratory applications
  • Warranty: StonyLab 1-year limited warranty; if received damaged, please contact us immediately; we will solve it until satisfied
No. 9
StonyLab Borosilicate Glass Graham Condenser with 24/40 Joint 200mm Jacket Length Lab Condenser
  • 200mm in jacket length.
  • Graham condenser is used for distillation and reflux apparatus.
  • Glass Graham condenser; 24/40 joint on the top and bottom.
  • G3.3 borosilicate glass, heavy duty design, reusable and corrosion resistance.
  • If received damaged, please let us know and we will solve it promptly.
No. 10
StonyLab Borosilicate Glass Graham Condenser with 24/40 Joint 500mm Jacket Length Lab Glass Condenser
  • Graham condenser is used for distillation and reflux apparatus, working with distillation flasks and bent adapters to condense vapors and liquid droplets
  • Glass Graham condenser; 24/40 joint on the top and bottom
  • Made of premium glass; maximum withstand temperature 200°C
  • 500mm in jacket length; hose fittings for 3.15in I.D. hoses
  • StonyLab ensures premium products and premium customer service; if received damaged, please contact us immediately; we will solve it until satisfied

Last update on 2026-07-18 / Affiliate links / Images from Amazon Product Advertising API

How to Choose the Best Lab Graham Condensers

Understanding Graham Condenser Types

Graham condensers are primarily distinguished by their joint sizes and the length of the inner coil. Common joint sizes include 14/20, 19/22, and 24/40, which must match other glassware in your setup. The length of the coil also impacts efficiency; longer coils offer more surface area for cooling, suitable for higher boiling point substances or faster condensation rates.

Materials and Durability

Most laboratory condensers are constructed from borosilicate glass, known for its thermal shock resistance and chemical inertness. This material is crucial for withstanding temperature fluctuations during heating and cooling cycles. Inspect the glass for any imperfections, such as chips or cracks, which could compromise the integrity of the condenser during use.

Coil Design and Surface Area

The effectiveness of a Graham condenser hinges on its internal coil design. The helical (coiled) shape significantly increases the surface area available for heat exchange between the vapor and the cooling fluid circulating through the outer jacket. Ensure the coil is uniformly constructed and free from obstructions to facilitate smooth vapor flow and efficient condensation.

Frequently Asked Questions

What is the primary function of a Graham condenser?
A Graham condenser is used to cool and condense hot vapors back into liquid form during laboratory processes like distillation and reflux. Its coiled inner tube provides a large surface area for efficient heat exchange with the circulating coolant.
What are the key factors to consider when choosing a size?
The most critical factor is the joint size, which must be compatible with other laboratory glassware. Additionally, the overall length and coil length of the condenser should be considered based on the volume and nature of the substances being processed.
Why is borosilicate glass the preferred material?
Borosilicate glass is chosen for its excellent resistance to thermal shock, meaning it can withstand rapid temperature changes without cracking. It also offers good chemical resistance, making it suitable for use with a wide range of solvents and reagents.
How does the coiled inner tube improve performance?
The helical shape of the inner tube greatly increases the surface area available for condensation compared to a straight tube. This enhanced surface area allows for more efficient transfer of heat from the vapor to the cooling water, leading to faster and more complete condensation.
What are the typical cooling fluids used with these condensers?
The outer jacket of the condenser is typically circulated with a cooling fluid, most commonly cold water. Other options include chilled water from a recirculator or specialized cooling baths for applications requiring very low temperatures.