Skip to content

Surface Roughness Comparators by Finish Process

As an Amazon Associate, we earn from qualifying purchases. Check the exact model, current price and availability with the retailer before buying.

Pick a surface roughness comparator by finish process first. Ground, turned and blast-cleaned surfaces can have different textures even when their reference numbers look similar. Match the process and parameter in the inspection requirement to the exact plate. We compared the options using published documentation. See the sources.

Choose by use

Metal reference coupons with several visibly different surface finishes
AI-generated illustration of the equipment category.

Compare the three options

Scroll horizontally to compare all columns.

Rubert Microsurf 315Rubert Microsurf 319Elcometer 125 Grit E125----1
Reference finishSurface grindingFace turningGrit-blasted steel
Reference valuesRa 0.025–3.2 µmRa 0.4–50 µm25, 60, 100 and 150 µm profile references
Number of reference patchesEightEightFour
ApplicationMachined surface comparatorMachined surface comparatorBlast-cleaned steel profile classification
Verify firstGround finish and RaFace-turned finish and RaAbrasive type and applicable procedure

Compare compatibility and trade-offs for your use. See sources and methodology

Options and trade-offs

Rubert Microsurf 315

For visual and tactile comparison of surface-ground finishes.

Rubert's 315 surface grinding plate offers eight reference patches spanning Ra 0.025 to 3.2 µm.

Keep in mind Check that surface grinding is the process named and that the drawing or quality plan asks for the Ra parameter within the plate's reference range.

Rubert Microsurf specimen specification tables

Rubert instrument reference specimens

Elcometer 125 Grit E125----1

For specified grit-blasted steel profile comparisons.

Elcometer lists four nominal reference profile values of 25, 60, 100 and 150 µm on its grit comparator. The company's shot comparator has a different reference set.

Keep in mind Confirm the drawing or project procedure calls for the grit profile comparator and review the applicable edition of the specified standard.

Elcometer 125 surface comparator catalog

Elcometer 125 datasheet

ISO 8503-1 summary

Match the reference texture to the production finish

The Microsurf catalog gives different part numbers for surface grinding, face turning and other named finishes. Confirm the intended comparator process with your quality lead. Choose a plate with reference patches that cover the roughness values on the drawing. [1] [4]

Read the parameter name alongside the number. Ra appears in Rubert's machined finish tables. Elcometer labels the listed values as blast profile references. Keep the parameter and standard wording from the inspection requirement when ordering. [1] [2] [3] [5]

Verify the blast reference before purchasing

Elcometer sells separate grit and shot versions of the 125. The reference values and textures for the two variants differ. Confirm which type your procedure calls for before placing the order. [2] [3]

ISO 8503-1 describes comparators for assessing blast-cleaned steel profiles visually and by touch. If the inspection paperwork specifies a standard or revision, check that the exact product has the documentation your team requires. [3] [5]

Choose an instrument when the report needs a measured value

A comparison plate gives reference patches. A procedure that requires a numerical result for each inspected part calls for a suitable measuring instrument and the calibration specified by the quality plan. [4] [5]

For a department using both plates and gauges, use separate labels for process comparators and instrument reference specimens. Rubert catalogs those two kinds of reference aids separately, so use the supplied documentation to verify which version you have. [1] [4]

Close-up of adjacent textured metal reference surfaces
AI-generated detail.

Common buying questions

Which Rubert plate covers surface grinding?

Microsurf 315 is the surface grinding comparator and lists eight patches from Ra 0.025 to 3.2 µm. [1]

Which comparator is for face turning?

Rubert model 319 is the face turning comparator. The catalog lists eight Ra reference patches from 0.4 to 50 µm. [1]

Can I choose a blasting comparator using a machined Ra target?

Choose by the inspection procedure and its parameter. The cited Elcometer profile references and the machined Ra references are different quantities. [1] [2] [3] [5]

How do I distinguish the Elcometer grit and shot plates?

Elcometer lists the grit plate as E125----1 and the shot plate as E125----2. The manufacturer's datasheet identifies the corresponding reference values. [2] [3]

Sources and methodology

We checked manufacturer process labels and reference ranges against the published standard summary. We show the comparator parameter for each model. See how we compare products.

  1. Rubert Microsurf specimen specification tables. Ground and face-turned comparator references, Ra values and specimen categories.
  2. Elcometer 125 surface comparator catalog. Exact grit and shot comparator identifiers and intended application.
  3. Elcometer 125 datasheet. Nominal micrometer profile references for grit and shot comparison plates.
  4. Rubert instrument reference specimens. Manufacturer distinction between instrument calibration specimens and samples for surface comparison.
  5. ISO 8503-1 summary. Explains the scope of visual and tactile comparators for blast-cleaned steel.

Before you choose

Compare specifications for the exact model and variant. Consider the dimensions, compatibility and maintenance that matter to your use. Customer ratings and product listings are different from independent hands-on testing.