Accurate temperature calibration is crucial for maintaining product quality, ensuring process efficiency, and meeting regulatory compliance in various industrial and scientific settings. Investing in a reliable temperature calibrator prevents costly errors and downtime. This guide will help you select the best device for your specific needs.
- Easy to read dual display lets you view input and output simultaneously
- Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters
- Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters
- Perform fast linearity tests with 25% and 100% steps
- Power transmitters during test using loop power supply with simultaneous mA measurement
- Multifunction Calibration - Sources and measures DC current (0-24 mA), voltage (0-20 V and 0-2000 mV), and eight thermocouple types (J, K, T, E, C, R, S, N), complete with Cold Junction Compensation.
- 24 V Loop Power - Provides loop excitation power for calibrating 2‑wire current transmitters without needing external power.
- User Presets & High Accuracy - Store up to five customizable calibration presets. Enjoy precision readings with typical accuracy of ±(0.01% + 1 digit) for current and voltage sources.
- Intuitive Display & Ergonomic Design - Large, backlit dot-matrix LCD housed in a palm-sized double-molded casing for readability and comfort in any environment.
- Ready-to-Use Kit - Includes test leads, alligator clips, thermocouple and universal calibration cables, a universal 100-240 VAC adapter with four international plugs, six AA batteries, and a rugged hard carrying case.
- Measure and simulate (17) different thermocouple types and millivolts
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Hanging tool designed in and included with every unit
- Configurable 0 % and 100 % source settings for quick 25 % linearity checks
- Linear ramp and 25% step auto ramp based on 0% and 100% settings
- VA710 Thermocouple Calibrator sources and measures 7 thermocouple type devices (J, K, T, E, R, S, B ,N) or mV (-10mV~100mV)
- Large 5 digit LCD with full angel
- High accuracy maximum up to 0.3°C and 0.025% for mV
- Measure or Simulating a Thermocouple
- Ambient temperature compensation and display
- Temperature Resolution: 0.1℃/0.1℉
- Temperature error: ± (0.3+10uV)
- Voltage range:-10mV-100mV
- Range: Ambient to 650°C | Accuracy: ±0.6°C | Bath Stability: ±0.05°C | Stabilization Time: 20 Min. | Heating Time: 30 to 32 Min. (Ambient to 650°C) | Resolution: 0.1°C | Units: °C / °F Switchable | Display: Graphical with LED Backlight | Power...
- Transmitter Supply: 24V DC ± 10% (Loop Powered) |Block Diameter: 25.4 mm | Block Depth: 120 mm | Insertion Tube Depth: 110 mm | Temperature Setting: Digital Display through feather touch keypad | Display Stability: ±0.2°C | Radial uniformity Fixed...
- Measuring Parameters: mA, mV, Volts, Ohms, RTD3 (Pt 100)3 | mA Range: 0 to 25 mA; Resolution: 0.001 mA; Accuracy: ±0.025% of Reading + 10 µA | mV Range: 0 to 1000.0 mV; Resolution: 0.01 mV; Accuracy: ±0.025% of Reading + 0.25 mV | Volts Range: 0 to...
- Thermocouple Types: T, J, K, N, R, S | Thermocouple Range( T,J,K,R,S): -200 to 400°C; Resolution: 0.1°C; Accuracy: ±0.025 % of Reading + 1°C |Thermocouple Range(R,S): 300 to 1760°C; Resolution: 1°C; Accuracy: ±0.025 % of Reading + 1°C |
- Supply Scope: 1 Unit of DBC-02 Dry Block Calibrator, Power Cable, 1 Unit of Test Lead (2 Wire), Insertion Tube: Dual Hole - 1 x 1/4” + 1 x 12.5 mm, Dual Hole - 1 x 1/4” + 1 x 8.2 mm, 1 Unit of Insertion Tool, 2no.s of 6A Spare Fuses, Instruction...
- High Precision: Achieve accurate results with source and measure accuracy up to 0.05%, ensuring reliable data in critical applications
- Multi-Sensor Capability: Measure and source 11 thermocouple types and 5 RTD types
- Adjustable Temperature Compensation: ensures accurate readings across different environments
- Multi-Wire Resistance Measurement: Conduct 2-, 3-, and 4-wire resistance measurements along with thermal resistance (RTD)
- Built-in Functions: Flashlight, Auto Power Off, Low Battery Indicator
- Measure and simulate (13) different RTD types and resistance
- Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Hanging tool designed in and included with every unit
- Configurable 0 % and 100 % source settings for quick 25 % linearity checks
- Linear ramp and 25% step auto ramp based on 0% and 100% settings
- Dry Block Temperature Calibrator Range: 50 to 650°C | Accuracy: ±0.6°C | Bath Stability: ±0.05°C | Stabilization Time: 20 Min. | Heating Time: 30 to 32 Min. (50 to 650°C) | Resolution: 0.1°C | Units: °C / °F Switchable | Display: Graphical with...
- Transmitter Supply: 24V DC ± 10% (Loop Powered) |Block Diameter: 25.4 mm | Block Depth: 120 mm | Insertion Tube Depth: 110 mm | Temperature Setting: Digital Display through feather touch keypad | Display Stability: ±0.2°C | Radial uniformity Fixed...
- Measuring Parameters: mA, mV, Volts, Ohms, RTD3 (Pt 100)3 | mA Range: 0 to 25 mA; Resolution: 0.001 mA; Accuracy: ±0.025% of Reading + 10 µA | mV Range: 0 to 1000.0 mV; Resolution: 0.01 mV; Accuracy: ±0.025% of Reading + 0.25 mV | Volts Range: 0 to...
- Thermocouple Types: T, J, K, N, R, S | Thermocouple Range( T,J,K,R,S): -200 to 400°C; Resolution: 0.1°C; Accuracy: ±0.025 % of Reading + 1°C |Thermocouple Range(R,S): 300 to 1760°C; Resolution: 1°C; Accuracy: ±0.025 % of Reading + 1°C
- Supply Scope: 1 Unit of DBC-02 Dry Block Calibrator, Power Cable, 1 Unit of Test Lead (2 Wire), Insertion Tube: Dual Hole - 1 x 1/4” + 1 x 12.5 mm, Dual Hole - 1 x 1/4” + 1 x 8.2 mm, 1 Unit of Insertion Tool, 2no.s of 6A Spare Fuses, Instruction...
- VA720 RTD Process Calibrator is a exactitude measurement and source instrument, it can be use to calibrate the RTD* transmitter (include most impulse transmitter).
- VA720 RTD Process Calibrator sources and measure 7 RTD type devices (PT10, PT50, PT100, PT200, PT500, PT1000(385), PT100(JIS) ) or Ω.
- Large 5 diqit LCD with full angel
- High accuracy maximum up to 0.2°C and 0.1Ω
- Mesurinag and Simulating RTD
- Temperature accurate to ±0.2°C with 0.1 Resolution
- Resistance accurate to ±0.1Ω with 0.1Ω resolution
- Range: Ambient to 350°C | Accuracy: ±0.4°C | Bath Stability: ±0.05°C | Stabilisation Time: 15 Min. | Heating Time: 18 to 20 Min. (Ambient to 350°C) | Cooling Time: 30 to 35 Min (350 to 100°C) | Resolution: 0.1°C | Units: °C / °F Switchable...
- Transmitter Supply: 24V DC ± 10% (Loop Powered) |Block Diameter: 25.4 mm | Block Depth: 120 mm | Insertion Tube Depth: 110 mm | Temperature Setting: Digital Display through feather touch keypad | Display Stability: ±0.2°C | Radial uniformity Fixed...
- Measuring Parameters: mA, mV, Volts, Ohms, RTD3 (Pt 100)3 | mA Range: 0 to 25 mA; Resolution: 0.001 mA; Accuracy: ±0.025% of Reading + 10 µA | mV Range: 0 to 1000.0 mV; Resolution: 0.01 mV; Accuracy: ±0.025% of Reading + 0.25 mV | Volts Range: 0 to...
- Thermocouple Types: T, J, K, N, R, S | Thermocouple Range(T,J,K,N): -200 to 400°C; Resolution: 0.1°C; Accuracy: ±0.025 % of Reading + 1°C | Thermocouple Range(R, S): 300 to 1760°C; Resolution: 1°C; Accuracy: ±0.025 % of Reading + 1°C |
- Supply Scope: 1 Unit of DBC-01 Dry Block Calibrator, Power Cable, 1 Unit of Test Lead (2 Wire), Insertion Tube: Dual Hole - 1 x 1/4” + 1 x 12.5 mm, Dual Hole - 1 x 1/4” + 1 x 8.2 mm, 1 Unit of Insertion Tool, 2no.s of 6A Spare Fuses, Instruction...
This article is part of our complete guide Industrial & Scientific — browse all our comparisons and buying guides.
Last update on 2026-07-09 / Affiliate links / Images from Amazon Product Advertising API
How to Choose the Best Temperature Calibrators
Accuracy and Stability
The primary function of a temperature calibrator is to provide a stable and accurate reference temperature. Look for devices with high accuracy ratings (e.g., +/- 0.1°C or better) and excellent temperature stability over time. This ensures that your measurements are precise and repeatable, which is critical for sensitive applications.
Temperature Range and Type
Consider the typical temperature range you need to calibrate. Calibrators come in various forms, including dry-block calibrators, liquid baths, and infrared calibrators. Dry-block calibrators are versatile and portable for many industrial uses, while liquid baths offer superior stability for certain lab applications. Ensure the chosen device covers your required temperature span, from sub-zero to high temperatures.
Portability and Ease of Use
For field calibration, portability and ease of use are important factors. Many modern calibrators are lightweight, compact, and feature intuitive user interfaces with clear displays. Features like quick heating/cooling times, built-in diagnostics, and data logging capabilities can significantly improve efficiency during calibration tasks.